Glossary of PLC Programming Terms

April 6, 2020

Whether you’re just starting out with industrial automation or you’ve been working in the field for years, this glossary of PLC programming terms will help you understand and communicate complex terms efficiently. The first section is specific programming terms. The second section is general terms surrounding PLC product styles and functionality. We hope you find this list useful as a reference for PLC terminology.

Programming Terms

  •  –   Bit – A bit is a single TRUE or FALSE (on or off)
  •  –   Bool – A bit that can be either TRUE or FALSE.
  •  –   Byte – A byte is 8 bits no sign (0 to 255)
  •  –   Char – A character is 8 bits no sign (0 to 255).
  •  –   ShortInt – A short integer is 8 bits (-128 to 127)
  •  –   Word – A word is 16 bits no sign (0 to 65535)
  •  –   Int – An integer is 16 bits (-32768 to 32767)
  •  –   UInt – An unsigned integer is 16 bits (0 to 65535)
  •  –   DInt –  A double integer is 32 bit (-2147483648 to 2147483647)
  •  –   Real – A real is 16 bit and has a decimal point(e.g. 123.45678).  Used for floating point numbers.
  •  –   DWord – A double word is 32 bit no sign (0 to 4294967295)
  •  –   LReal – A long real is 32 bit and has a decimal point(e.g. 123.45678).  Used for floating point numbers.  LReal has less round off error than a Real
  •  –   MB – Mega bytes. An MB is 1024 KB (1,048,576 bytes)
  •  –   GB – Giga bytes. A GB is 1024 MB (1,073,741,824 bytes)
  •  –   String – A string is a grouping of chars.
  •  –   Array – An array is a list of the same variable types using the same base name with an index
  •  –   A two speed array
    •  –   speed[0] := 10;
    •  –   speed[1] := 200;
  •  –   Structure – A structure is a group of variables of same or different types put together for easier handling.
    •  –   A structure called T_DRIVE

TYPE T_DRIVE :
STRUCT

Homingrate : INT;
Jograte : INT;
Target : DINT;
Controlword : WORD;

END_STRUCT
END_TYPE

    •  –   Example code

VAR Drive : T_DRIVE
Drive.Homingrate := -5;
Drive.Jograte := 20;
Drive.Target := 374000;
Drive.Controlword := 0001;

General Terms

  •  –   Capacitive Touch – Devices like iPhones and other smart phones use a capacitive touch screen. the screen senses the extra capacitance of the human finger to determine if the screen is being “pressed”. A user cannot use a screw driver – the screen will not respond. One negative of capacitive touch screens: users cannot operate the screen wearing gloves, unless they are special gloves designed for touch screen use. Not all safety gloves have this feature.  Multi-touch functionality allows PDFs to be viewed with zoom in/out functionality.  (See the KEB S14)
  •  –   CPU – Main processor in a control.
  •  –   CPU Type/Speed – Comparing CPU types and clock speeds can only offer an idea that one iPC is faster than another. One CPU may run at 1 GHz and the other may only run at 500 Mhz, but if the 500 Mhz CPU has floating point arithmetic and the 1 GHz does not, then the 500 MHz CPU will be many times faster running a motion profile than the 1 GHz processor.
  •  –   Cycle/Loop Time – See scan time
  •  –   Distributed IO – IO modules that are distributed about a machine. (See the KEB Remote IO)
  •  –   DCS – Distributed Control System. A type of PLC or iPC that works by itself to control a certain part of a larger process (e.g. refinery).
  •  –   Embedded Control – Another version of a PAC.  (See the KEB C6 SMART)
  •  –   Execution Time – The time it takes a PLC or control to execute (scan) through the code once. Control performance and code size define this time. If the time is too slow, a faster processor/control or code rework is required. The control typically has some tool that can show the code execution time.
  •  –   Fieldbus – A communication system between devices (bus system). A fieldbus is typically serial, Ethernet, or fiber based. As an analogy, the telephone is to people as a fieldbus is to a machine.
  •  –   Frame – Similar to a telegram. Can also refer to part of a telegram – something like, “data frame”
  •  –   Function – A simple routine that executes and returns a value, but doesn’t store anything. An example is a square root routine (value in / value out).
  •  –   Function Block Diagram (FBD) – A piece of code that can be reused. Each reuse creates a new instance (independent execution) of itself. FBs can store values for future use (counters, timers, history, etc).
  •  –   HMI – Human Machine Interface. Also known as a touch screen display. HMIs connect to PLCs or other controls and provide a way for machine users to control the machine or view performance data. Only necessary data is transmitted between the HMI and control (via some type of fieldbus). HMIs have to be programmed and are responsible for actually drawing the screens and handling the user data entry.  (See KEB HMI or S14).
  •  –   Instance – A copy of code with it’s own variable space. For example, each drive has it’s own jog speed, home position, target position.
  •  –   IO – Inputs and Outputs. With traditional PLCs, they wer handled with IO cards that handle 4, 8, 16, or 32 inputs or outputs. Supported signals include digital and analog.  Some cards also have small relay outputs for 120 VAC logic.
  •  –   Industrial Ethernet – A buzz word within the machine/automation industry describing the adoption of Ethernet connectivity into machinery. EtherCAT is one such solution.
  •  –   Instruction List (IL) – One of the IEC 61131-3 programming languages.  A low-level assembly like language.  Programs in a list of basic instructions.
  •  –   iPC – Industrial PC.  Purpose build PCs that are intended for industrial environments.  They are designed to limit component failures by not using fans and using components like Solid-state drives instead of hard drives.  Chipsets and Operating Systems are selected to provide a defined lifecyle of support.  (See the KEB E22 and P34)
  •  –   Jitter – Variation between one execution time to another. Code typically require more or less calculations during one scan versus another. This results in a different execution time. Jitter is important for higher performance coordinated motion systems.
  •  –   Ladder Diagram (LD) – One of the IEC 61131-3 programming languages.  A graphical programming language that is processed with rungs, much like actual relay logic.
  •  –   Line (Point to Point) Connection – Devices are daisy chained together in one line to the control.
  •  –   M2M – Machine to Machine connectivity.
  •  –   Main loop – Main program loop the control executes over and over
  •  –   Master – Device that is in charge or talks first over a bus system. Sometimes this is a master encoder that sets the overall line speed of a machine. It can also be a Fieldbus Master which talks to/controls a number of Slave devices.
  •  –   Min/Max Cycle Time – Fastest and Slowest execution time seen. These values are used to determine Jitter and are also used to determine what scan time to select.
  •  –   Mixed Connection – A combination of line and star connections.
  •  –   Motion Control – Commonly refers to an option card for a PLC (motion card). Also can refer to functionality instead of hardware.  (See the KEB C6 SMART)
  •  –   OPC – OLE for Process Control (Object Linking and Embedding). Provides a method to connect and control industrial automation products independent of the vendor (brand). KEB C6 controls can connect to an OPC system.
  •  –   OS – Operating System. Windows, Linux, etc.
  •  –   PAC – Programmable Automation Control. Higher performance than a PLC and focused more on motion and automation instead of IO.  (See the KEB C6 SMART)
  •  –   PLC – Programmable Logic Control. Microprocessor based.  Historically, programmed in ladder logic. Accepts accessory IO modules. PLCs originally replaced relays wired together (relay logic)
  •  –   (PLC) Rack – Older PLCs had a backplane (rack) that could power and process a certain amount of IO modules. Newer solutions might connect via a communication bus.  (See KEB EtherCAT IO)
  •  –   Process Data – Data that is predefined to be sent consistently over the Fieldbus. For example, the H6, F6, S6 can have 8 parameters for process data read and 8 for process data write. Every EtherCAT scan, the 8 write parameters are written and the 8 read parameters are read.
  •  –   Program (PRG) – A block of code that only has one instance.
  •  –   Real-time – A controller and/or fieldbus that runs fast enough to be considered the same as real-time reaction or response. KEB EtherCAT drives can run with update rates as low as 125 us.  Most control systems will typically be set to run at 1 or 4 ms.  Most motors (aka 1 Hp larger) and mechanical systems cannot respond in 4 ms, meaning the solution is effectively real-time.
  •  –   Remote IO – IO modules that are not installed directly on the control. Allows for easier wiring of large machines where sensors and switches can be a long ways away from the control.  (See KEB EtherCAT IO).
  •  –   Resistive Touch – 4 wire/5 wire – Resistive grid touch screen. Resistive screens work by having a two layer overlay on the screen. A finger (or other item) depresses the outer film creating a resistive connection between the two layers of film. The X and Y position is determined by the resistance value. Smaller screens use a 4 wire solution and larger screens use a finer 5-wire solution. One negative of resistive touch screens: a user may use a screw driver to operate the screen (it works) and may damage the display.  (See KEB HMI)
  •  –   Ring Connection – The control and devices are daisy-chained together in a circle (the control is wired to the start and end of a line connection).  Ring topology requires two EtherCAT masters (three ports, two EtherCAT and one Ethernet). If there is a cable break, all devices still get the controls messages and the control can see the cable is broken and react.
  •  –   RTE – Run Time Environment. A run time environment provides the system to run our programming code.
  •  –   RTU – Remote Terminal Unit. Generic term used for either a dumb or smart device at a remote location which must collect/provide some data when asked.
  •  –   SCADA – Supervisory Control and Data Acquisition. The basic concept is to connect devices over large geographical areas (thousands of miles) to gather/share data. SCADA systems are used in electrical transmission utilities, wastewater/treatment, oil fields, etc. In automation, customers refer to SCADA more as a concept of connection/operation.
  •  –   Scan Time – The time between executing code cycles. The minimum time is the same as execution time (free running). Most systems define a fixed interval that is slower than the execution time, so the scan time becomes fixed. Update rates of Inputs and outputs are directly affected by scan time. Example: execution time = 1.4 ms, set scan time = 2 ms.
  •  –   Slave – Device that responds to a master. This can be a slave drive that is electronically geared to a master drive. It can also be a Fieldbus slave that responds to the Fieldbus Master.
  •  –   Star Connection – The control is the center with each device connecting directly to the control.
  •  –   Structured Text (ST) – One of the IEC 61131-3 programming languages.  A high level language that uses IF-THEN-ELSE statements.  Also, WHILE-DO.
  •  –   Tag – Used by people familiar with PLC/HMI programming. A tag points to a memory location. A tag is functionally the same a variable.
  •  –   Telegram – The actual message used by a Fieldbus. It is typically only referred to when you discuss “telegram structure”
  •  –   Update Rate – See scan time

Important Links Bar.jpg

https://www.kebamerica.com/blog/glossary-of-plc-programming-terms/

 

Related Articles

Network Infrastructure Featured Product Spotlight

PBUS 14 Panduit logo 400

This webinar presented by Beth Lessard and Keith Cordero will be highlighting three Panduit solutions that will optimize network equipment and cabling to ensure that your spaces are efficiently and properly managed to support ever-evolving business needs of today and beyond. Products that will be featured include PanZone TrueEdge Wall Mount Enclsoure, Cable Managers, and Adjustable Depth 4-Post Rack.

REGISTER HERE


Editor’s Pick: Featured Product News

Siemens: SIMOVAC Non-Arc-Resistant and SIMOVAC-AR Arc-Resistant Motor Controllers

The Siemens SIMOVAC medium-voltage non-arc-resistant and SIMOVAC-AR arc-resistant controllers have a modular design incorporating up to two 12SVC400 (400 A) controllers, housed in a freestanding sheet steel enclosure. Each controller is UL 347 class E2, equipped with three current-limiting fuses, a non-load-break isolating switch, and a fixed-mounted vacuum contactor (plug-in type optional for 12SVC400). The enclosure is designed for front access, allowing the equipment to be located with the rear of the equipment close to a non-combustible wall.

Read More


Sponsored Content
Electrify Your Enterprise

Power is vital to production, and well-designed control cabinets are key. Allied Electronics & Automation offers a comprehensive collection of control cabinet solutions including PLCs, HMIs, contactors, miniature circuit breakers, terminal block connectors, DIN-rail power supplies, pushbutton switches, motor starters, overloads, power relays, industrial Ethernet switches and AC drives engineered to keep your operations running safely, reliably and efficiently.

Learn more HERE.


Products for Panel Builders

  • Celduc: New SMQR Quad Series Solid State Relay

    Celduc: New SMQR Quad Series Solid State Relay

    Celduc’s Solid State Relays are designed for industrial applications where fast and long electrical life in switching is required. Celduc has recently launched a new range of Quad AC Output Solid State Relay. With this new SMQR Series you will get four independently controlled AC output Solid State Relays in an industry standard package. With the models… Read More…

  • Brady: M211 Portable Bluetooth Label Printer

    Brady: M211 Portable Bluetooth Label Printer

    Design. Preview. Print. All from your phone. The M211 portable Bluetooth label printer is a tough, compact labeler that belongs on any jobsite. Seamlessly design, preview and print labels right from Brady’s Express Labels Mobile app for iOS and Android. Create custom labels from your phone’s familiar keyboard via ultra strong BLE Bluetooth technology. Maximize… Read More…