Halogen-free cables are a required staple in a vast number of industrial and infrastructural applications. Over time, different labels for these cables have been established, such as FRNC, HFFR, LS0H, or LSZH. But how meaningful are these abbreviations, and what are the benefits of halogen-free cables compared to products containing halogens? Let HELUKABEL explain.

Halogens (which means “to form salt”) include the chemical elements chlorine (Cl), bromine (Br), fluorine (F), and iodine (I). When manufacturing cables, these are used to make certain conductor insulation and jacketing materials flame retardant. This is where chlorine (which is a component of PVC plastic or chloroprene rubber) and fluorine (which is found in the high-temperature materials FEP, PTFE, and ETFE) come into play. Even bromine is used in flame retardants for cables and wires.

The problem is that halogens burn extremely aggressively and emit noxious fumes when ignited. They produce halogen halides that turn into acids when they come into contact with moisture and can cause acid burns in the respiratory tract. Furthermore, the acids that are released can cause metal parts to corrode, damaging machines and even the rebar reinforcements of concrete in buildings. This can result in the need for time-consuming and costly decontamination efforts.

Cable and wire flame retardancy is an important criterion for fire prevention measures. There are also a number of applications that explicitly require halogen-free products, which means cables and wires consisting of materials that are free of chlorine, bromine, fluorine, and iodine. Should these cables be ignited, they produce much less acid and smoke, and are less toxic, which substantially reduces the consequential damage to people, buildings, and machines. However, poisonous gases such as carbon monoxide are still emitted when halogen-free cables are ignited.

Halogen-free cables and wires are required in buildings where people gather and where valuable material assets must be protected, for example. These include:

  • Building technology: In public buildings such as offices, shopping centers, schools, hospitals, and airports, strong fire and health risk prevention ordinances are in place. Most of the cables and wires in these places are fixed in their installation and do not need to fulfill any special chemical or mechanical requirements. PE or PP-based plastic mixtures are often used here, which are halogen free and flame retardant, and produce little smoke or toxic gas. They must also often pass bundle burning tests.
  • Industrial automation: · Machines and plants often require cables and wires with high chemical and mechanical resistances. When used in flexible applications such as in drag chains or in robotics, these loads are especially high. Typically, jacket mixtures based on TPE-O or TPE-U (PUR or Santoprene) are used here. These are also available with halogen-free constructions but are not able to be manufactured to be as flame retardant or low smoke as cables for building technology.

Typical Labels for Halogen-Free Cables

Over the years, different manufacturers, markets, regions, and standards have developed different labels for halogen-free and flame-retardant cables:

  • FRNC Flame Retardant Non Corrosive
  • HFFR Halogen Free Flame Retardant
  • LS0H Low Smoke 0 Halogen (also: LSOH)
  • LSZH Low Smoke Zero Halogen

None of these labels, however, deliver concrete information regarding flame retardancy, corrosiveness, toxicity, and light attenuation. Users must therefore pay close attention to the standards listed in the data sheets of each supplier. The information listed there is the only way to identify the flammability properties of a cable (horizontal, vertical, or bundle burning tests).

Which Standards are Typical for Halogen-Free Cables?

  • DIN EN 60754-1 VDE 0482-754-1:2021-02 defines the testing machines and the testing procedures required to identify the total acidity. The test result must show values lower than 5mg/g to be certified as halogen-free.
  • DIN EN 60754-2 VDE 0482-754-2:2021-02 defines the measurement of the pH value and conductivity. The test result for the pH value must be below 4.3 and for conductivity, it must be under 10µS/mm.
  • DIN EN 61034-2 VDE 0482-1034-2:2021-02 defines the measurement of smoke gas density of burning cables. The test result must show a light attenuation of no more than 40% to be considered low smoke. Depending on the application, customer, and region, lower light attenuation can be required. The goal is for people to be able to still recognize the source of the fire, as well as possible escape routes. These standards are required in public buildings and trains due to the high density of people present.

Take Away

In many applications where safety is critical, halogen-free cables and wires offer substantial advantages, as less toxic gas and smoke is emitted in the case of a fire. At the same time, these products must exhibit high flame retardancy in order to comply with different standards and requirements. It is not enough to rely on the common labels of FRNC, HFFR, LS0H, or LSZH to determine the actual flame retardancy of a cable.

The standards named in data sheets are the only information you should rely on. It is through these standards that users can determine whether the product is considered to have low, middle, or high flame retardancy, if they are constructed to be low smoke, or if they have been tested for light attenuation. As experts for electrical connection technology with more than 45 years of experience, HELUKABEL is happy to help you identify the most ideal cables and wires for your application.

Important_Links_Bar.jpg

https://www.helukabel.us/us-en/Newsroom/Item/flame-resistance-halogen-free-cables.html

Related Articles

Network Infrastructure Featured Product Spotlight

PBUS 14 Panduit logo 400

This webinar presented by Beth Lessard and Keith Cordero will be highlighting three Panduit solutions that will optimize network equipment and cabling to ensure that your spaces are efficiently and properly managed to support ever-evolving business needs of today and beyond. Products that will be featured include PanZone TrueEdge Wall Mount Enclsoure, Cable Managers, and Adjustable Depth 4-Post Rack.

REGISTER HERE


Editor’s Pick: Featured Product News

Siemens: SIMOVAC Non-Arc-Resistant and SIMOVAC-AR Arc-Resistant Motor Controllers

The Siemens SIMOVAC medium-voltage non-arc-resistant and SIMOVAC-AR arc-resistant controllers have a modular design incorporating up to two 12SVC400 (400 A) controllers, housed in a freestanding sheet steel enclosure. Each controller is UL 347 class E2, equipped with three current-limiting fuses, a non-load-break isolating switch, and a fixed-mounted vacuum contactor (plug-in type optional for 12SVC400). The enclosure is designed for front access, allowing the equipment to be located with the rear of the equipment close to a non-combustible wall.

Read More


Sponsored Content
Electrify Your Enterprise

Power is vital to production, and well-designed control cabinets are key. Allied Electronics & Automation offers a comprehensive collection of control cabinet solutions including PLCs, HMIs, contactors, miniature circuit breakers, terminal block connectors, DIN-rail power supplies, pushbutton switches, motor starters, overloads, power relays, industrial Ethernet switches and AC drives engineered to keep your operations running safely, reliably and efficiently.

Learn more HERE.


Products for Panel Builders

  • SCHURTER: Green Line – Portfolio Expanded

    SCHURTER: Green Line – Portfolio Expanded

    SCHURTER significantly expands its portfolio of “Green Line” connectors. Because wherever you can reduce your CO₂ footprint without compromising on quality, you really should do so. As with the launch of the first series of Green Line products, SCHURTER remains true to its policy of offering a version with plant-based housings for products that are… Read More…

  • AutomationDirect: Teknokol Eco Series HMI Enclosures and Suspension Arm Systems

    AutomationDirect: Teknokol Eco Series HMI Enclosures and Suspension Arm Systems

    AutomationDirect has added Teknokol Eco series HMI enclosures and suspension arm systems which are designed to work together to provide customized, adjustable HMI panels using a selection of components and cut-to-length arm profiles. These suspension systems allow the HMI to be relocated as needed for better HMI visibility and operator comfort.  The medium-duty TK060 series… Read More…